Adjustable Register Plate - 125mm Hole 900mm x 495mm - 2 Access Holes

Adjustable Register Plate - 125mm Hole 900mm x 495mm - 2 Access Holes


Register Plates are used to seal off the base of the chimney.
This Register Plate is ADJUSTABLE by 80mm from front to back. Its overall size is 900mm x 495mm
It has TWO access holes.
It is suitable for 125mm (5 inch) Black Stove Pipe.
DO NOT USE THIS REGISTER PLATE IF YOU ARE USING VERMICULITE TO INSULATE YOUR FLUE.

 

APPLICATION
Use to seal off the base of the chimney (This Register Plate can be cut on site to fit the base size of your chimney stack). The Register Plate will support vermiculite and stop any debris from within the chimney stack coming down the chimney and hitting your stove.

CONSTRUCTION
The Register Plate and the Supporting Brackets are made from 1.5mm thick galvanised steel. The Register Plate can be sprayed to match the colour of your stove pipe. This Register Plate has a special adapter suitable for installations which use either 125mm or 150mm diameter flue pipes.

INSTALLATION
The four supporting brackets should be cut to the length and width of the base of your chimney stack. Drill a number of holes in the brackets. Now screw them into the brickwork. Cut the Register Plate to the correct size, taking care that the pipe hole lies vertically above the Black Stove Pipe. Drop the Register Plate onto the supporting brackets. Now seal any gaps between the brickwork and the brackets / plate using Fire Cement or High Temperature Sealant. For 150mm diameter installations simply remove the centre cover ring by unscrewing the two retaining screws.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year. At the same time remove the Register Plates inspection hole cover plate(s) and hoover / sweep any debris that has fallen.
DO NOT REMOVE COVER PLATES IF VERMICULITE HAS BEEN INSTALLED AS ADDED INSULATION.

Monday, 28 October 2013

Quattro-PLUS Flue Liner 316L Grade - Solid Fuel 125mm (5 inch)

** Quattro-PLUS Flue Liner 316L Grade - Solid Fuel 125mm (5 inch)

Multi fuel flexible liner made from 316L grade stainless steel - 10 year manufacturers warranty with this product



WARRANTY
316L Grade Flue Liner is warranted for 10 years (conditions apply)

APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat.
If the appliance is mainly going to be used to burn wood, and the appliance is not DEFRA approved you should increase the diameter of the Flue Liner to 150mm (providing this will fit in the masonry chimney), as recommended by Building Regulations.

CONSTRUCTION
The flue liner has a smooth inner liner made from 316L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 316L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.

APPROVAL
Flue Liner is approved and listed by HETAS

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.


MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Wednesday, 23 October 2013

ULISSE Log Trolley


ULISSE Log Trolley

This carriage has been designed for logs which are a maximum of 500mm long.
It is equiped with a stainless steel handle and a 3mm thick steel body.
The rear wheels have a diameter of 150mm.
The revolving front wheels allow the trolley to be manourvered easily.
All four wheels are made from grey rubber that will protect delicate flooring.
It is powder coated in an opaque black colour.
Self assembly.

Friday, 18 October 2013

RES 2 Lead Base 175-275mm (7-11 inch) - Low Temp.

RES 2 Lead Base 175-275mm (7-11 inch) - Low Temp.

Suitable for tiled roofs with external pipe diameters of 7inch to 12inch (175mm to 300mm), the maluble LEAD base size is 27inch x 27inch.
APPLICATIONSuitable for tiled roofs and is temperature resistance -55°C to 135°C
CONSTRUCTIONThe EPDM rubber upstand has a 20 year life. The built in 20° pitch allows adaptability to almost any roof pitch including 45°. The pull tab design and easy smooth tear grooving is intended to eliminate cutting by knife and allow for a circular hole.
INSTALLATION1. Pull tab design to correct size using pliers, alternatively cut using a stanley knife.
2.Apply silicone sealant to back of flashing.
3.Remove tiles around pipe and slide flashing over pipe.
4. Fasten Flashing to the roof.
5. Cut tile to fit tp the top of the Flashing allowing the bottom of the flashing metal base to sit on top of the tiles.

Tuesday, 15 October 2013

POD Twelve - 7 kW Stove

POD Twelve - 7 kW

The Pod Twelve has a steel body giving a maximum of 10kw of heat with a nominal output of 7kw. A contemporary design with a large ceramic curved glass front giving an excellent view of the fire, the stove is beautifully styled. The stove has a log store under the fire chamber. The stove is available in matt brown. Internally it’s fully lined with firebricks.

The Pod Twelve is certified to BS EN13240 and comes with a 2 year warranty.

Monday, 14 October 2013

ULISSE Log Trolley

ULISSE Log Trolley

This carriage has been designed for logs which are a maximum of 500mm long.
It is equiped with a stainless steel handle and a 3mm thick steel body.
The rear wheels have a diameter of 150mm.
The revolving front wheels allow the trolley to be manourvered easily.
All four wheels are made from grey rubber that will protect delicate flooring.
It is powder coated in an opaque black colour.
Self assembly.

Tuesday, 1 October 2013

Quattro-PLUS Flue Liner 904L Grade - Solid Fuel 250mm (10 inch)

** Quattro-PLUS Flue Liner 904L Grade - Solid Fuel 250mm (10 inch)

Multi fuel flexible liner made from 904L grade stainless steel on both the inner and outer walls - 25 year manufacturers warranty with this product
 
WARRANTY
904L Grade Flue Liner is warranted for 20 years (conditions apply)

APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, smokeless fuels.

CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 904L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.

APPROVAL
Flue Liner is approved and listed by HETAS

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.


MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.